HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Common Replacement Information and Procedures
77HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Caution: You must disable the ECB before disconnecting the ECB Y-cable
from the cache module. Failure to disable the ECB can damage the cache
module.
8. If not already done, disable the ECB by pressing the battery disable switch for
approximately 5 seconds.
9. Connect the ECB Y-cable to the cache module.
10. If not already connected, connect a PC or terminal to the controller
maintenance port.
11. Restart the controller by pressing the Reset button.
Note: A controller restart can take as long as 60 seconds, indicated by the temporary
cycling of the port LEDs and a flashing Reset button.
Note: If the controller did not restart, use the following steps:
a. Press and hold the controller Reset button.
b. Reseat the controller program card.
c. Release the Reset button.
12. From the CLI prompt, display details about the configured controller using
the following command:
SHOW THIS_CONTROLLER FULL
13. Set the date and time by using the following command, if necessary:
SET THIS_CONTROLLER TIME=dd-mm-yyyy:hh:mm:ss
14. Mount the logical units on the host.
15. For Windows 2000 or Windows NT platform users, restart the server.
16. Disconnect the PC or terminal from the controller maintenance port.