HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Common Replacement Information and Procedures
86 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
1. Verify which RAIDset is to be moved (see Figure 29).
Figure 29: Display showing the RAIDset to be moved.
2. Delete the RAIDset on “this controller” (see Figure 30).
Figure 30: Deleting the RAIDset on the originating subsystem
g_top> show r5
Name Storageset Uses Used by
--------------------------------------------------------------------
R5 raidset DISK21200 D5
DISK21300
DISK21400
DISK21500
Switches:
POLICY (for replacement) = BEST_PERFORMANCE
RECONSTRUCT (priority) = NORMAL
CHUNKSIZE = 256 blocks
State:
NORMAL
DISK21200 (member 0) is NORMAL
DISK21300 (member 1) is NORMAL
DISK21400 (member 2) is NORMAL
DISK21500 (member 3) is NORMAL
Size: 106643109 blocks
g_top> del d5
g_top> del r5
g_top> del disk21200
g_top> del disk21300
g_top> del disk21400
g_top> del disk21500