HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Common Replacement Information and Procedures
89HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
6. Verify that the RAIDset is moved and configured correctly, and that the one
disk is moved to the failedset.
Figure 35: Display showing the configured RAIDset
Figure 37 on page 90 displays the disk that is moved to the failedset.
zBot> show r5
Name Storageset Uses Used by
----------------------------------------------------------------------------
R5 raidset DISK20400 D5
DISK50300
DISK60200
Switches:
POLICY (for replacement) = BEST_PERFORMANCE
RECONSTRUCT (priority) = NORMAL
CHUNKSIZE = 256 blocks
State:
REDUCED
DISK60200 (member 1) is NORMAL
DISK20400 (member 2) is NORMAL
DISK50300 (member 3) is NORMAL
Size: 106643109 blocks