Common Replacement Information and Procedures
98 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Wait for Port to quiesce. Go to the side of cab from where you remove the disk
drive and wait approximately 10-15 seconds. The port
is quiesced, when
all
the disk drives on that port show
a flashing amber LED.
Note: If the disk drive on that port has the locate light
function enabled, the disk drive LED for that device is
solid until the quiesce sequence is over, at which time it
begins to flash and the other devices stops flashing.
Promptly - physically remove disk drive
about 2.54 cm (1–in) out, then give disk
drive time to spin-down (60 seconds).
Complete removal process.
Both array controllers port lights remain solid and the
disk drive lights goes off. Within about 20 seconds of
device removal, device activity begins to resume on the
remaining units. The period of time is load dependent.
Installing disk drive into slot. Verify that 2 minutes have passed since disk drive
removal installation.
On the HSG80 controller, press the port
button of the physical port containing the
disk drive to be removed.
Press the port button for about 2 seconds and then
release. When the action is recognized by the HSG80
array controller, all the port lights on the HSG80 array
controller bulkhead flashes on for about 1 second.
Then, the port light on the HSG80 array controller
begins to pulse.
Note: Remember to press the correct port button.
Wait for Port to quiesce. Go to the side of cab from where you remove the disk
drive and wait approximately 10-15 seconds. The port
is quiesced when
all
the disk drives on that port have a
flashing amber LED.
Physically push disk drive into the shelf. Within about 20 seconds of device insertion, the device
activity to other storage resumes. Both array controller
port lights turn off and the disk drive lights go off (if no
disk drive faults on that port).
CLI Commands to HSG80 or Actions Comments