HP StorageWorks HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software V8.7A for Novell NetWare Release Notes

Documentation Anomalies
Release Notes – HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution
Software Version 8.7A for Novell NetWare
28
Mounting a CLONE
Before mounting a CLONE, make sure you move it to another system. Having two
identical NetWare Volume Names on the same system can cause problems. NetWare
does not allow you to mount a SNAPHOT on the same server that hosts the original
volume. NetWare views the SNAPSHOT as a software mirror of the original volume
and does not allow you to mount both copies on the same server. The SNAPSHOT can
only be mounted on another NetWare server.
Cluster Configurations
If using an array in a cluster configuration, leave 5 MB free on one array for cluster
configuration information.
SCSI-2 Configurations
Do not use LUN 0 with Novell NetWare in multi-bus failover mode. Do not use LUN
0 or LUN 100 with Novell NetWare in transparent failover mode.
SCSI-3 Mode
SCSI-3 Mode is now supported under NetWare.
NSS Partitions
NSS partition creation is supported by this Solution Software under NetWare.
Documentation Anomalies
All references to StorageWorks Command Console (SWCC) in the HSG80 ACS
Solution Software Version 8.7 for Novell Netware Installation and Configuration
Guide are no longer valid. SWCC no longer ships with the HSG80 Modular
Storage RAID Arrays Solution Software V8.7A. Refer to "Controller
Configuration with NetWare", page 23, for replacement options.