HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)

Installing and Configuring HSG Agent
144 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
6. Follow the on-screen prompts to complete installation.
7. After rebooting all necessary hosts, login as root and enter the following
command:
/installation_directory/steam/bin/config.sh
The RAID Array Configuration menu is displayed.
8. Select option 13 and press Enter to add a subsystem.
Notice SPT is now the driver on the HP-PB bus adapter.
9. Select option C to continue.
The computer displays the subsystems connect to your host, as shown in the
following example:
Processing Host gemini
Node HW Path Driver Device
-------- ------------------ ------- --------
gemini 8/0.8.0.255.0.2.0 sdisk HSGCCL
gemini 8/4.8.0.255.0.2.0 sdisk HSGCCL
gemini 10/4/12.0.0 spt HSZ70CCL
gemini 10/4/12.0.0 spt HSZ70CCL
Found 4 Command Console LUNs on host aries.
To remove a CCL enter: “r hardware_path”, to add enter “a”
Would you like to Add, Remove or Continue? [a,r,C]
The SPT driver is now attached to both HP-PB bus adapters.
10. Select option C to continue.
The computer updates the storage.ini files for each host.
11. Enter a name for your subsystem.
12. Enter a desired monitoring period in seconds. The default is 180 seconds.
The following is displayed:
Completed checking pass thru driver installation and special
files.
Updating storage.ini files for each host.
For each subsystem the computer finds, it asks you to enter a name for the
subsystem and a desired monitoring period.
13. When you are asked to start
Steam_pkg, enter Y. Steam_pkg is the name of the
HS-Series Agent daemon. This daemon must be running for it to monitor your
subsystems and for it to provide status updates to your Client systems.