HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)

Installing and Configuring HSG Agent
148 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
Configuring the Agent for an Alternate Path
1. Go to the RAID Array Configuration menu by entering the following
command:
# /installation_directory/steam/bin/config.sh
Note: For HP-UX, only one alternate path is supported in transparent failover mode.
2. Select option 15 to modify a subsystem.
3. Enter the position number of the subsystem to modify.
4. Select option 4, alternate device.
5. Enter whether you want to add or remove a device.
6. Enter an alternative access device. The following is an example of the name of
the device that you may enter:
For SCSI-2: ../dev/rdsk/c9t1d0
For SCSI-3: ../dev/rscsi/c9t1do
7. Follow the on-screen prompts.