The node ID is located in the third line of the SHOW THIS result:
HSG80> SHOW THIS
Controller:
HSG80 ZG80900583 Software V8.8, Hardware E11
NODE_ID = 5000-1FE1-0001-3F00
ALLOCATION_CLASS = 0
If the node ID is present, go to step 5.
If the node ID is all zeroes, enter node ID and checksum, which are located on
a sticker on the controller enclosure. Use the following syntax to enter the
node ID:
SET THIS NODE_ID=NNNN-NNNN-NNNN-NNNN nn
Where:NNNN-NNNN-NNNN-NNNN is the node ID, and nn is the checksum.
2. When using a controller that is not new from the factory, enter the following
command to take it out of any failover mode that may have been configured
previously:
SET NOFAILOVER
If the controller did have a failover mode previously set, the CLI may report
an error. Clear the error with this command:
CLEAR_ERRORS CLI
3. Enter the following command to remove any previously configured
connections:
SHOW CONNECTIONS
A list of named connections, if any, opens.
4. Delete these connections by entering the following command:
DELETE !NEWCON01
Repeat the Delete command for each of the listed connections. When
completed, no connection opens.
Configuring Controller Settings
5. Set the SCSI version using the following command syntax: