HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)

FC Configuration Procedures
156 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
Note: SET THIS SCSI_VERSION=SCSI-2, or If SCSI-2 is selected, you must disable
CCL using the command:
SET THIS NOCOMMAND_CONSOLE_LUN
6. Assign an identifier for the communication LUN (also called the command
console LUN, or CCL). The CCL must have a unique identifier that is a
decimal number in the range 1 to 32767, and which is different from the
identifiers of all units. Use the following syntax:
SET THIS IDENTIFIER=N
Identifier must be unique among all the controllers attached to the fabric
within the specified allocation class.
7. Set the topology for the controller. If both ports are used, set topology for both
ports:
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
If the controller is not factory-new, it may have another topology set, in which
case these commands results in an error message. If this happens, take both
ports offline first, then reset the topology:
SET THIS PORT_1_TOPOLOGY=OFFLINE
SET THIS PORT_2_TOPOLOGY=OFFLINE
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
8. Set Allocation class to a decimal number between 0 and 999. The number
must be unique across the fabric. Set allocation class using the following
syntax:
SET THIS ALLOCATION_CLASS=N
Restarting the Controller
9. Restart the controller, using the following command:
RESTART THIS