HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)

FC Configuration Procedures
157HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
10. Assign an identifier for the communication LUN (also called the command
console LUN, or CCL). The CCL must have a unique identifier that is a
decimal number in the range 1 to 32767, and which is different from the
identifiers of all units. Use the following syntax:
SET THIS IDENTIFIER=N
Identifier must be unique among all the controllers attached to the fabric
within the specified allocation class.
Setting Time and Verifying All Commands
1. Set the time on the controller by entering the following syntax:
SET THIS TIME=DD-MMM-YYYY:HH:MM:SS
2. Use the FRUTIL utility to set up the battery discharge timer. Enter the
following command to start FRUTIL:
RUN FRUTIL
When FRUTIL asks if you intend to replace the battery, answer Y:
Do you intend to replace this controller's cache battery? Y/N
[N] Y
FRUTIL prints out a procedure, but does not give you a prompt. Ignore the
procedure and press the Enter key.
3. Set up any additional optional controller settings, such as changing the CLI
prompt. See the
SET THIS CONTROLLER/OTHER CONTROLLER command in the HP
StorageWorks HSG60 and HSG80 Array Controller and Array Controller
Software Command Line Interface Reference Guide for the format of optional
settings.
4. Verify that all commands have taken effect. Use the following command:
SHOW THIS
Verify node ID, allocation class, SCSI version, failover mode, identifier, and
port topology.