HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)

FC Configuration Procedures
158 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
The following sample is a result of a SHOW THIS command, with the areas of
interest in bold.
Controller:
HSG80 ZG94214134 Software V8.8, Hardware 0000
NODE_ID = 5000-1FE1-0007-9750
ALLOCATION_CLASS = 01
SCSI_VERSION = SCSI-3
Configured for dual-redundancy with ZG9421461
In dual-redundant configuration
Device Port SCSI address 7
Time: 10-Mar-2002:12:30:34
Command Console LUN is disabled
Smart Error Eject Disabled
(IDENTIFIER = 88)
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0007-9751
PORT_1_TOPOLOGY = FABRIC (fabric up)
Address = 7D4000
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0007-9752
PORT_2_TOPOLOGY = FABRIC (standby)
Address = 210513
NOREMOTE_COPY
Cache:
512 megabyte write cache, version 0022
Cache is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
Mirrored Cache:
Not enabled
Battery:
NOUPS
FULLY CHARGED
Expires: 25-JUN-2003