HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)

FC Configuration Procedures
170 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
Configuring a Stripeset
1. Create the stripeset by adding its name to the controller's list of storagesets
and by specifying the disk drives it contains. Use the following syntax:
ADD STRIPESET STRIPESET-NAME DISKNNNNN DISKNNNNN.......
2. Initialize the stripeset, specifying any desired switches:
INITIALIZE STRIPESET-NAME SWITCHES
See "Specifying Initialization Switches", page 95, for a description of the
initialization switches.
3. Verify the stripeset configuration:
SHOW STRIPESET-NAME
4. Assign the stripeset a unit number to make it accessible by the hosts. See
"Assigning Unit Numbers and Unit Qualifiers", page 175.
For example:
The commands to create Stripe1, a stripeset consisting of three disks
(DISK10000, DISK20000, and DISK10100) and having a chunksize of 128:
ADD STRIPESET STRIPE1 DISK10000 DISK20000 DISK30000
INITIALIZE STRIPE1 CHUNKSIZE=128
SHOW STRIPE1
Configuring a Mirrorset
1. Create the mirrorset by adding its name to the controller's list of storagesets
and by specifying the disk drives it contains. Optionally, you can append
mirrorset switch values:
ADD MIRRORSET MIRRORSET-NAME DISKNNNNN DISKNNNNN SWITCHES
Note: See the ADD MIRRORSET command in the
HP StorageWorks HSG60 and
HSG80 Array Controller and Array Controller Software Command Line Interface
Reference Guide
for a description of the mirrorset switches.
2. Initialize the mirrorset, specifying any desired switches:
INITIALIZE MIRRORSET-NAME SWITCHES
See "Specifying Initialization Switches", page 95, for a description of the
initialization switches.