HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)

FC Configuration Procedures
171HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
3. Verify the mirrorset configuration:
SHOW MIRRORSET-NAME
4. Assign the mirrorset a unit number to make it accessible by the hosts. See
"Assigning Unit Numbers and Unit Qualifiers", page 175.
For example:
The commands to create Mirr1, a mirrorset with two members (DISK10000 and
DISK20000), and to initialize it using default switch settings:
ADD MIRRORSET MIRR1 DISK10000 DISK20000
INITIALIZE MIRR1
SHOW MIRR1
Configuring a RAIDset
1. Create the RAIDset by adding its name to the controller's list of storagesets
and by specifying the disk drives it contains. Optionally, you can specify
RAIDset switch values:
ADD RAIDSET RAIDSET-NAME DISKNNNNN DISKNNNNN DISKNNNNN SWITCHES
Note: See the ADD RAIDSET command in the
HP StorageWorks HSG60 and HSG80
Array Controller and Array Controller Software Command Line Interface Reference
Guide
for a description of the RAIDset switches.
2. Initialize the RAIDset, specifying any desired switches:
INITIALIZE RAIDSET-NAME SWITCH
Note: HP recommends that you allow initial reconstruct to complete before allowing
I/O to the RAIDset. Not doing so may generate forced errors at the host level. To
determine whether initial reconstruct has completed, enter
SHOW RAIDSET FULL.
See "Specifying Initialization Switches", page 95, for a description of the
initialization switches.
3. Verify the RAIDset configuration:
SHOW RAIDSET-NAME