Configuring a Single-Disk Unit (JBOD)
1. Initialize the disk drive, specifying any desired switches:
INITIALIZE DISK-NAME SWITCHES
See "Specifying Initialization Switches", page 95, for a description of the
initialization switches.
2. Verify the configuration by entering the following command:
SHOW DISK-NAME
3. Assign the disk a unit number to make it accessible by the hosts. See
"Assigning Unit Numbers and Unit Qualifiers", page 175.
Configuring a Partition
1. Initialize the storageset or disk drive, specifying any desired switches:
INITIALIZE STORAGESET-NAME SWITCHES
or
INITIALIZE DISK-NAME SWITCHES
See "Specifying Initialization Switches", page 95, for a description of the
initialization switches.
2. Create each partition in the storageset or disk drive by indicating the
partition's size. Also specify any desired switch settings:
CREATE_PARTITION STORAGESET-NAME SIZE=N SWITCHES
or
CREATE_PARTITION DISK-NAME SIZE=N SWITCHES
where N is the percentage of the disk drive or storageset that is assigned to the
partition. Enter
SIZE=LARGEST, on the last partition only, to let the controller
assign the largest free space available to the partition.
Note: See the CREATE_PARTITION command in the
HP StorageWorks HSG60 and
HSG80 Array Controller and Array Controller Software Command Line Interface
Reference Guide
for a description of the partition switches.
3. Verify the partitions:
SHOW STORAGESET-NAME