HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)

FC Configuration Procedures
174 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
or
SHOW DISK-NAME
The partition number is displayed in the first column, followed by the size and
starting block of each partition.
4. Assign the partition a unit number to make it accessible by the hosts. See
"Assigning Unit Numbers and Unit Qualifiers", page 175.
For example:
The commands to create RAID1, a three-member RAIDset, then partition it into
two storage units are shown below.
ADD RAIDSET RAID1 DISK10000 DISK20000 DISK30000
INITIALIZE RAID1
CREATE_PARTITION RAID1 SIZE=25
CREATE_PARTITION RAID1 SIZE=LARGEST
SHOW RAID1