HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)

FC Configuration Procedures
177HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
Configuration Options
There are multiple options that allow you to configure your system.
Changing the CLI Prompt
To change the CLI prompt, enter a 1- to 16- character string as the new prompt,
according to the following syntax:
SET THIS_CONTROLLER PROMPT = “NEW PROMPT”
If you are configuring dual-redundant controllers, also change the CLI prompt on
the “other controller.” Use the following syntax:
SET OTHER_CONTROLLER PROMPT = “NEW PROMPT”
Note: It is suggested that the prompt name reflect some information about the
controllers. For example, if the subsystem is the third one in a lab, name the top
controller prompt, LAB3A and the bottom controller, LAB3B.
Mirroring Cache
To specify mirrored cache, use the following syntax:
SET THIS MIRRORED_CACHE
Adding Disk Drives
If you add new disk drives to the subsystem, the disk drives must be added to the
controllers’ list of known devices:
To add one new disk drive to the list of known devices, use the following
syntax:
ADD DISK DISKNNNNN P T L
To add several new disk drives to the list of known devices, enter the
following command:
RUN CONFIG
Adding a Disk Drive to the Spareset
The spareset is a collection of spare disk drives that are available to the controller
should it need to replace a failed member of a RAIDset or mirrorset.