HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)

FC Configuration Procedures
181HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
Verifying Storage Configuration from Host
This section describes how to verify that LUNs (virtual disk units) are being
correctly presented to HP-UX.
After configuring units (virtual disks) through either the CLI restart the host. If
you are adding units dynamically, then use
ioscan and insf -e commands to
verify that the device special files and logical unit numbers are created and
correctly assigned to each storageset.
Verify that the units are correctly presented to the host by entering the following
command:
ioscan -fnCdisk
Class I H/W Path Driver S/W State H/W Type Description
==========================================================
disk 0 0/0/1/0.1.0 sdisk CLAIMED DEVICE HP DVD-ROM 6x/32x
/dev/dsk/c0t1d0 /dev/rdsk/c0t1d0
disk 1 0/0/2/0.6.0 sdisk CLAIMED DEVICE SEAGATE ST39102LC
/dev/dsk/c1t6d0 /dev/rdsk/c1t6d0
disk 8 0/0/2/1.6.0 sdisk CLAIMED DEVICE SEAGATE ST39204LC
/dev/dsk/c2t6d0 /dev/rdsk/c2t6d0
disk 12 0/10/0/0.8.0 sdisk CLAIMED DEVICE DEC HSG80
/dev/dsk/c6t8d0 /dev/rdsk/c6t8d0
disk 13 0/10/0/0.8.1 sdisk CLAIMED DEVICE DEC HSG80
/dev/dsk/c6t8d1 /dev/rdsk/c6t8d1
disk 14 0/10/0/0.12.0 sdisk CLAIMED DEVICE DEC HSG80
/dev/dsk/c6t12d0 /dev/rdsk/c6t12d0
For more details on using the CLI, refer to the HP StorageWorks HSG60 and
HSG80 Array Controller and Array Controller Software Command Line Interface
Reference Guide.
For more details on using SWCC, see the HP StorageWorks Command Console
V2.5 User Guide.