HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)

Planning Storage Configurations
74 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
Table 5: PTL addressing, dual-bus configuration, three Model 4350R enclosures
Model 4350R Disk Enclosure Shelf 1 (Single-bus)
SCSI Bus A SCSI Bus B
Bay 1 2 3 4 5 6 7 8 9 10
SCSI
ID
00 01 02 03 04 00 01 02 03 04
DISK
ID
Disk10000
Disk10100
Disk10200
Disk10300
Disk10400
Disk20000
Disk20100
Disk20200
Disk20300
Disk20400
Model 4350R Disk Enclosure Shelf 2 (Single-bus)
SCSI Bus A SCSI Bus B
Bay
1 2 3 4 5 6 7 8 9 10
SCSI
ID
00 01 02 03 04 00 01 02 03 04
DISK
ID
Disk30000
Disk30100
Disk30200
Disk30300
Disk30400
Disk40000
Disk40100
Disk40200
Disk40300
Disk40400
Model 4350R Disk Enclosure Shelf 3 (single-bus)
SCSI Bus A SCSI Bus B
Bay
1 2 3 4 5 6 7 8 9 10
SCSI
ID
00 01 02 03 04 00 01 02 03 04
DISK
ID
Disk50000
Disk50100
Disk50200
Disk50300
Disk50400
Disk60000
Disk60100
Disk60200
Disk60300
Disk60400