Compaq StorageWorks UltraSCSI RAID Enclosure (DS-BA370 Series) User's Guide (EK-BA370-UG. C02, September 1998)

Single-Ended I/O Module
5–12 UltraSCSI RAID Enclosure
Cabling a Two-Enclosure Subsystem
Complete the procedures in Table 5–6 to connect the master enclosure
to one expansion enclosure. Perform this procedure for the I/O
modules on each SCSI bus, starting with SCSI bus 1 in Figure 5–3.
Each SCSI bus requires one BN37A cable for a total of six cables.
Caution
Not all array controllers support an UltraSCSI RAID
subsystem with more than one enclosure. Refer to the array
controller documentation to ensure the controller supports
expanded configurations.
Overtightening the I/O module spring-loaded mounting
screws can damage the threads.
Table 5–6 Installing Two-Enclosure Subsystem
Cables
1. Complete Table 5–5 to shut down the UltraSCSI subsystem.
2. Use a screwdriver to loosen two spring-loaded mounting screws on
the I/O module.
3. Grasp the I/O module by
the cable support bracket
and pull it straight
outward until removed
from the enclosure
shroud.
4. Repeat steps 2 and 3 for all the I/O modules.
CXO5816A