Forces the controller to recognize a failed device, regardless of the controller
evaluation of the device condition. A device failure can cause the controller to
label the device as unknown. After that happens, the controller does not check the
device again to see if it was repaired or if the error condition was corrected. You
must enter this command so the controller can recognize the device after the cause
of the error was corrected.
Syntax
CLEAR_ERRORS device-name UNKNOWN
Note: The keyword UNKNOWN cannot be abbreviated.
Parameters
The following parameter supports the CLEAR_ERRORS device-name
UNKNOWN command:
device-name
Identifies the device with the unknown error.
Switches
There are no switches associated with this command.
Example
To force the controller to recognize a previously unknown device named
DISK30000, enter:
CLEAR_ERRORS DISK30000 UNKNOWN
CLEAR_ERRORS
device-name