HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
107HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Clears an unwriteable data error on a unit. This command affects all partitions on
the same container. If a storageset or disk drive fails before its data is written to it,
the controller reports an unwriteable data error. The CLEAR_ERRORS
unit-number UNWRITEABLE_DATA command removes the data from the
cache and clears the unwriteable data error.
Caution: This command causes data loss.
Syntax
CLEAR_ERRORS unit-number UNWRITEABLE_DATA
Note: Because misuse of this command causes data loss, the command cannot be
abbreviated.
Parameters
The following parameter supports the CLEAR_ERRORS UNWRITEABLE_DATA
command:
unit-number
Identifies the unit having the unwriteable data error. The unit-number is
the name given to the unit at the time it was created with the ADD UNITS
command.
Switches
There are no switches associated with this command.
CLEAR_ERRORS
unit-number
UNWRITEABLE_DATA