HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
110 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
The following provides guidelines for establishing a configuration after using the
CONFIGURATION RESET command:
For single-controller subsystems, follow the configuration information
guidelines below:
New subsystem configuration information can be re-entered by using the
SET THIS_CONTROLLER command.
Saved subsystem configuration information can be re-established by
using the CONFIGURATION RESTORE command.
For dual-redundant controller subsystems, follow the configuration
information guidelines below:
Dual-redundant controller subsystems have the configuration information
stored on the “other controller” and do not need to use the INITIALIZE
container-name SAVE_CONFIGURATION command.
New subsystem configuration information can be re-established by using
the SET FAILOVER COPY=controller or SET
MULTIBUS_FAILOVER COPY=controller command. These CLI
commands copy the configuration file from the defined controller
nonvolatile memory and place the file into the redundant controller
nonvolatile memory. For example, use SET FAILOVER
COPY=OTHER_CONTROLLER or SET MULTIBUS_FAILOVER
COPY=OTHER_CONTROLLER executed from “this controller” to place
the “other controller” configuration file into the “this controller”
nonvolatile memory.
Tip: An alternative method for erasing subsystem configuration data stored in
NVRAM is through the controller operator control panel (OCP). To initiate the
CONFIGURATION RESET command through the OCP:
1. Push and hold the Port #5 button, and then momentarily press the Reset button.
2. Continue holding the Port #5 button until the Port #5 button LED starts flashing.
3. Release the Port #5 button.
Refer to the
HP StorageWorks HSG60 and HSG80 Array Controller and Array
Controller Software Maintenance and Service Guide
for configuration reset usage in
controller replacement instructions for single-controller and dual-redundant
subsystems.