HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
141HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
CAPACITY=n (1 to the maximum container size in blocks)
Note: After executing the INITIALIZE command with the CAPACITY switch,
it appears that the command did not complete because the SHOW disk-name
command does not display any change to the size. It shows the total size of the
disk, not the new size.
The new size is not seen until the corresponding unit is added. The command
SHOW disk-name displays the new size.
Example:
HSG80> INITIALIZE DISKxxxxx CAPACITY=4000000
HSG80> SHOW DISKxxxxx
Note: The new capacity is not seen after this command.
To show the new size, enter:
HSG80> ADD UNIT Dx
HSG80> SHOW Dx
CYLINDERS=n (1 to16,777,215)
HEADS=n (1 to 255)
SECTORS_PER_TRACK=n (1 to 255)
Sets the geometry switches reported to the host.
Note: The geometry switches should not be used unless there is a compatibility
problem with the existing defaults.
The geometry switches for the INITIALIZE command are ignored after you create
partitions. The geometry switches supplied with the CREATE_PARTITION command
are used by the unit.