HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
149HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Note: Only one of the following parameters can be entered with each LOCATE
command.
ALL
Causes the device fault LEDs of all configured devices to flash. Specify ALL
to test all of the LEDs at once.
CANCEL
Turns off all device fault LEDs turned on with the LOCATE command.
container-name
Causes the device fault LEDs on the devices within the container-name to
flash. If a device name is given, the device fault LED flashes. If a storageset
name is given, the fault LED on all of the devices assigned to the storageset
flashes.
DISKS
Causes the device fault LEDs on all configured disks to flash.
ptl (scsi-port-target-lun)
Causes the device fault LED on the device at the given SCSI location to flash.
UNITS
Causes the device fault LEDs on all devices used by the units to flash.
Tip: This parameter is useful for determining which storage devices are not currently
configured into logical units.
unit-number
Causes the device fault LEDs on the devices making up the unit-number
to flash.