HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
162 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
SPECIAL_FUNCTION_ONE=INFO
Directs the controller to examine RAID5-only containers and report:
Which devices, if any, have metadata attributes that are inconsistent as a
result of sparing operations to RAID5 sets while operating under ACS
V8.7-2 through V8.7-7.
Which devices have partition flags, no partition flags, or inconsistencies
on associated containers.
Whether attached units exist, if any.
Note: Issuing this command displays information for only those containers or units
that are online or assigned to the controller from which the command is issued. If you
issue this switch with the REINITIALIZE
container-name command for a
RAIDset on another controller, the following message displays:
Error 9620: Information not available on this controller.
Enter command on other controller.
SPECIAL_FUNCTION_ONE=PARTITION
Directs the controller to set the partition flag bits on all devices in a container
and establishes the container as a partitioned container. This command can
only be used with RAIDset containers.
Caution: Ensure that the container was previously initialized as a partitioned
container before using this command. Failure to do so results in loss of access
to partitioned data.
Note: Issuing the SPECIAL_FUNCTION_ONE=PARTITION or the
SPECIAL_FUNCTION_ONE=PARTITION switch in dual-redundant controller
configurations causes the container ownership to move to the controller from which the
REINITIALIZE
container-name command was
not
issued.