HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
164 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Example
Figure 5: Screen display after issuing the REINITIALIZE
SPECIAL_FUNCTION_ONE=INFO command
See Also
CONFIGURATION SAVE
INITIALIZE
HSG_TOP> REINITIALIZE R1 SPECIAL_FUNCTION_ONE=INFO
Unit: D7, Type: Un-partitioned
Raidset: R1
Device: DISK10200, Marked partitioned: No, Structure version
Affected: No, mdata_version (vsi): 11
Device: DISK30200, Marked partitioned: No, Structure version
Affected: No, mdata_version (vsi): 11
Device: DISK20200, Marked partitioned: Yes, Structure version
Affected: Yes, mdata_version (vsi): 11