Causes the controller to attempt to write previously unwriteable data from the
writeback cache to the specified devices. No data is lost if the retry fails.
If a container fails in a way that prevents the data in writeback cache to be written
to the container, an unwriteable data error is reported.
Syntax
RETRY_ERRORS unit-number UNWRITEABLE_DATA
Parameter
The following parameter supports the RETRY_ERRORS command:
unit-number
Identifies the unit number to which the data contained in writeback cache tries
to write. The unit number is the same name given to the unit after it was
created using the ADD UNITS command.
Switches
There are no switches associated with this command.
Example
To retry the writing of the cached data previously marked unwriteable to
disk unit D103, enter:
RETRY_ERRORS D103 UNWRITEABLE_DATA
See Also
CLEAR_ERRORS unit-number UNWRITEABLE_DATA
RETRY_ERRORS