HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
174 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Specify IGNORE_ERRORS to instruct the controller to ignore any
writeback cache errors. Such errors can result from data contained within
writeback cache that cannot be written to devices or lost data errors.
Specify NOIGNORE_ERRORS to instruct the controller not to run the
self-test program if writeback cache errors are detected.
IMMEDIATE_SHUTDOWN
NOIMMEDIATE_SHUTDOWN
(default)
Instructs the controller on whether to flush the writeback cache.
Caution: The IMMEDIATE_SHUTDOWN switch instructs the controller to
immediately shut down, without regard to any data contained within
writeback cache. Do not perform any hardware changes until the controller
flushes the cache.
Select IMMEDIATE_SHUTDOWN to instruct the controller to run the
self-test program immediately without flushing user data from writeback
cache to devices.
Select NOIMMEDIATE_SHUTDOWN to instruct the controller to flush
data from writeback cache before running the self-test program.
Examples
To start the self-test program on “this controller,” enter:
SELFTEST THIS_CONTROLLER
To run the self-test program on the “other controller,” even if the “other
controller” cannot flush all data from the writeback cache, enter:
SELFTEST OTHER_CONTROLLER IGNORE_ERRORS
See Also
RESTART controller
SHUTDOWN controller