HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
188 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Controls whether newly added units can automatically allow connections
between a Fibre Channel adapter in a host computer and an active host port on
a controller.
Note: The default controller behavior of enabling all connections is retained after ACS
V8.8-
x
is installed to maintain compatibility with user scripts.
With this command, both controllers have the same setting and the setting
does not change after a controller reboot.
Note: Although the HP StorageWorks HSG Element Manager and HP StorageWorks
Command Console disable all connections for units created through their respective
programs, creating new units through the CLI requires you to manually disable
connections unless you set the default access setting to
DISABLE_ALL.
IDENTIFIER=n
NOIDENTIFIER
Determines how the command console LUN (CCL) is identified by the host
operating system.
Specify IDENTIFIER to provide an alternative way (other than a World
Wide Name) for some operating systems to identify the command console
LUN (CCL).
Specify IDENTIFIER with the SCSI_VERSION switch if the SCSI
version is set to SCSI-3 mode. The IDENTIFIER switch creates a CCL
identifier that makes the controller and the CCL visible to the host. This
number can be a value between 1–9,999.
Tip: OpenVMS configures DGA units based on the identifier value that is presented
from the controller. You cannot present multiple units from the controller with the same
identifier to a single OpenVMS node or single OpenVMS cluster; otherwise,
unpredicable mounting results occur.