HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
193HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Figure 6: Location of node ID sticker on a BA370 enclosure
PORT_1_AL_PA=n
PORT_2_AL_PA=n
Specifies the arbitrated loop physical address (AL-PA) for the host ports
(used only in Fibre Channel arbitrated loop (FC-AL) topology). This switch
works only if LOOP_HARD is specified for the PORT_1_TOPOLOGY or
PORT_2_TOPOLOGY switch. The range of addresses allowed is 0-EF
(hexadecimal).
The factory settings for AL-PA are 71 for port 1 and 72 for port 2. If the
controller memory is wiped out, the AL-PA for both ports defaults to 69.
1 Node ID 2 Checksum
CXO6873B
WWN INFORMATION
P/N:
WWN:
Checksum:
NNNN – NNNN – NNNN – NNNN
NN
S/N:
1
2