HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
196 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Note: After submitting this command, a controller restart is required.
SCSI_VERSION=SCSI-2
(default)
SCSI_VERSION=SCSI-3
Specifies the host protocol to use. SCSI-3 means that the controller uses some
SCSI-3 commands. It does not mean that it is a fully-compliant SCSI-3
device. The CCL presents to the host a LUN through which it communicates
with the controller.
A side effect of the SCSI mode is how the command console LUN (CCL) is
handled.
Specify SCSI-2 to set the CCL as not fixed at a particular location, but
floats depending on the configuration.
Specify SCSI-3 to set the CCL as fixed at LUN 0. The SCSI device-type
returned to the host controller.
Changes to this switch take place at the next controller restart.
Note: In SCSI-2 mode, if the Command Console LUN (CCL) is enabled, and in SCSI-3
mode where the CCL is always enabled, the result is 127 visible LUNs and one CCL.
SMART_ERROR_EJECT=SMART ERROR EJECT
Removes drives in a normalized and redundant set that reports smart errors.
Smart errors that are reported by drives in a nonredundant or non-normal set
continue to handle this condition as a recovered error.
If the Smart Error Eject state is disabled, all smart errors are reported as
recovered errors. The recovered error report contains ASC 0x5D, the ASC for
all smart errors, and the appropriate ASCQ. The default value for this feature
is disabled.
Note: Configuration changes to disk drive SMART attributes support HP standards.
SMART attributes events are only reported as recovered errors and will be reported to
the host during normal I/O operations.