HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
197HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
TERMINAL_PARITY=ODD
TERMINAL_PARITY=EVEN
NOTERMINAL_PARITY
(default)
Specifies the parity with which data is transmitted and received. If changed,
the new setting for this switch takes effect immediately.
TERMINAL_SPEED=baud-rate
TERMINAL_SPEED=9600
(default)
Sets the terminal transmission and reception speed (baud rate) to 4,800, 9,600
(default), or 19,200 baud. If changed, the new value entered for this switch
takes effect immediately.
TIME=dd–mmm–yyyy:hh:mm:ss
Sets the date and time using a 24-hour clock. The time is set on both
controllers in a dual-redundant configuration. If changed, the new value
entered for this switch takes effect immediately.
UPS=NODE_ONLY
UPS=DATACENTER_WIDE
NOUPS
Specifies whether the controller should perform regular battery condition
checks. Setting the UPS or NOUPS switch for either controller sets the switch
for both controllers. Both controllers must be restarted in order for the new
setting to take effect.
Specify UPS=NODE_ONLY if the storage subsystem power is supplied by
a separate uninterruptible power supply (UPS) directly connected to a
power verification and addressing (PVA) module. If NODE_ONLY is
specified the controller continues to check the condition of the cache
batteries.
Caution: Setting UPS=NODE_ONLY or UPS=DATACENTER_WIDE without
having a UPS or similar backup system in place can result in data loss if
power is interrupted.