HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
198 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Specify UPS=DATACENTER_WIDE if the whole room or building (not
just the subsystem) is supported by a UPS. If DATACENTER_WIDE is
specified, the controller does not check the condition of the cache
batteries and ignores the battery state. This causes RAIDsets and
mirrorsets to always be available, regardless of the condition of the cache
batteries.
Specify NOUPS to instruct the controller to perform regular cache battery
checks and evaluate the condition of the cache batteries.
Examples
To change the “this controller” CLI prompt, enter:
SET THIS_CONTROLLER PROMPT=“TOP”
To change the “other controller” CLI prompt, enter:
SET OTHER_CONTROLLER PROMPT=“CONTROLLER B”
To set the name of the controller pair and put the controller pair in Remote Copy
mode, enter:
SET THIS_CONTROLLER REMOTE_COPY=LONDON
Note: The “other controller” in the pair automatically receives the same name.