HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
212 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Enables changes to the automatic replacement policy for the failedset.
Syntax
SET FAILEDSET
Parameters
There are no parameters associated with this command.
Switches
The following switch supports the SET FAILEDSET command:
AUTOSPARE
NOAUTOSPARE
Specifies the policy to be used by the controller if a disk drive is physically
replaced in the failedset.
Specify AUTOSPARE to instruct the controller to automatically move
devices physically replaced in the failedset into the spareset.
Specify NOAUTOSPARE to instruct the controller to leave devices
physically replaced in the failedset. The device, though replaced, remains
in the failedset until it is manually removed with the DELETE
FAILEDSETS command.
In most circumstances, a disk physically replaced into the failedset is
functional and contains no metadata and is a new device that has not been
initialized. If you specify the AUTOSPARE switch after a disk is physically
replaced in the failedset, the controller checks to see if any metadata is
present. If the controller detects metadata, the disk remains in the failedset. If
the controller does not detect metadata, the controller automatically initializes
the disk and moves it from the failedset to the spareset. Now a member of the
spareset, the disk is available for any mirrorset or RAIDset requiring a
replacement member. If the automatic initialization fails, the disk remains in
the failedset.
SET FAILEDSET