HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
221HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Places “this controller” and the “other controller” into Multiple-bus Failover
mode. Failover is a process that allows a controller to take over total control of the
storage subsystem in the event of the failure of its companion controller.
Note: Remove all connections that appear using the SHOW CONNECTIONS command
before establishing Multibus Failover mode.
Note: Before putting the controllers in Multiple-bus Failover mode, remove any
previous Transparent Failover mode with the SET NOFAILOVER command.
Syntax
SET MULTIBUS_FAILOVER COPY=controller
Parameters
There are no parameters associated with this command.
Switches
The following switch supports the SET MULTIBUS_FAILOVER command:
COPY=controller
Identifies which controller contains the source configuration. You must
specify THIS_CONTROLLER (the one connected to the CLI maintenance
terminal) or OTHER_CONTROLLER. The companion controller receives the
configuration information and restarts.
Caution: Verify which controller has the good configuration information
before entering this command. The device configuration information from the
controller specified by the
controller parameter overwrites the
information on the companion controller.
SET MULTIBUS_FAILOVER