HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
223HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
The SET NOFAILOVER and SET NOMULTIBUS_FAILOVER commands
remove “this controller” and the “other controller” (if currently reachable) from
Failover mode. Either command can be used to cancel failover, as they both
perform exactly the same actions.
The controller on which the command was entered is always removed from the
Dual-redundant mode, even if the second controller is not currently reachable. No
configuration information is lost. All units that were accessed through the “other
controller” fail over to “this controller,” and the “other controller” is shut down.
Note: Immediately after entering this command, one controller should be physically
removed because the sharing of devices is not supported by single controller
configurations.
HP recommends that both controllers be present while this command is submitted.
Otherwise, the controllers become misconfigured with each other, requiring additional
steps later to allow the “other controller” to be configured for failover.
The SET NOFAILOVER and SET NOMULTIBUS_FAILOVER commands
affect both controllers, regardless of the controller on which the command is
carried out.
Syntax
SET NOFAILOVER
or
SET NOMULTIBUS_FAILOVER
Parameters
There are no parameters associated with this command.
SET NOFAILOVER