HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
257HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Example
To display the full information for a controller, enter the SHOW controller
FULL (see Figure 16).
Figure 16: Screen display after issuing the SHOW controller FULL command
SHOW OTHER_CONTROLLER FULL
Controller:
Copyright 2002-2003 Hewlett-Packard Development Company, L.P.
HSG80 Software version 88F-1, Hardware version 0000
NODE_ID = 5000-1FE1-0005-9C10
ALLOCATION_CLASS = 1
SCSI_VERSION = SCSI-2
Configured for MULTIBUS_FAILOVER with ZG95005203
In dual-redundant configuration
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is lun 0 (NOIDENTIFIER)
Host Connection Table is NOT locked
Smart Error Eject Disabled
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0005-9C13
PORT_1_TOPOLOGY = FABRIC (connection down)
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0005-9C14
PORT_2_TOPOLOGY = FABRIC (connection down)
NOREMOTE_COPY
Cache:
32 megabyte write cache, version 0012
Cache is GOOD
Unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
Mirrored Cache:
32 megabyte write cache, version 0012
Cache is GOOD
Unflushed data in cache
Battery:
NOUPS
FULLY CHARGED
Expires: 04-MAY-2005
Extended information:
Terminal speed 19200 baud, eight bit, no parity, 1 stop bit
Operation control: 00000000 Security state code: 25059
Configuration backup disabled
Unit Default access enabled
SCSI Fairness Disabled
Vendor ID: DEC