HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
283HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Example
Figure 21: Screen display after issuing the SHOW mirrorset-name command
See Also
ADD MIRRORSETS
DELETE container-name
SHOW MIRRORSETS
SHOW STRIPESETS
BOT> show M1
Name Storageset Uses Used by
------------------------------------------------------------------
M1 mirrorset DISK10000 S1
DISK20000
DISK20400
Switches:
POLICY (for replacement) = BEST_PERFORMANCE
COPY (priority) = NORMAL
READ_SOURCE = LEAST_BUSY
MEMBERSHIP = 3, 3 members present
State:
RECONSTRUCTING
DISK20000 (member 0) is NORMAL
DISK20400 (member 1) is NORMAL
DISK10000 (member 2) is COPYING 6% complete
Size: 71114623 blocks