HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
310 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Allows you to assign a WWID number to a valid storageset. The ASSIGN
<storage set> LUN_WWID= command cannot be used under the following
circumstances:
On concatenated sets
If an uninitialized container is specified
If a duplicate WWID is being specified that exists in this subsystem
If trying to assign a WWID to a unit
If trying to assign a WWID to a transportable disk
If trying to assign a WWID on a partitioned container
If trying to assign a WWID on a concatenated set
Note: If you had a previous unit under a known WWID address on the controller, you
can assign the previous WWID address to a different or new unit if:
The base WWID is for the current controller pair.
The WWID that is entered is
not
currently duplicated on the controller.
Note: If you are running ACS V8.8-
x
P (DRM) and operating under the condition of a
site failover and wanting to make the assignment of a remote copy set unit (as
presented to the host) of a WWID in the range of the initiator site WWID, you can do
so if the following conditions are met:
The unit is assigned a WWID that is different than the base WWID for the
controller pair is an RCS unit.
ACS V8.8-
x
P is the operating firmware on your subsystem.
Syntax
WWID_ASSIGN storageset LUN_WWID=
Parameters
There are no parameters associated with this command.
WWID_ASSIGN
storageset
LUN_WWID=