HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
57HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Parameters
The following parameters support the ADD CONNECTIONS command:
connection-name
HOST_ID
ADAPTER_ID
CONTROLLER
PORT
REJECTED_HOST
These parameters are described in the following paragraphs.
connection-name
Identifies the name assigned to the host connection. The
connection-name can consist of a maximum of nine printable characters
excluding brackets, commas, and backslashes.
The controller automatically assigns a default connection name if a
connection is physically made between a host adapter and a controller port.
The form of a default connection name is !NEWCONnn.
HOST_ID=host-id
Identifies the World Wide Name (WWN) of the host. The WWN is a
16-character hexadecimal number. The hyphens are not necessary but are
recommended to avoid mistakes in entering the number. The host ID
parameter name must be entered, followed by an equal sign, and then
followed by the WWN of the host.
For example, to specify a WWN of AAAA-BBBB-CCCC-DDDD, enter:
HOST_ID=AAAA-BBBB-CCCC-DDDD
ADAPTER_ID=adapter-id
Identifies the WWN of the host Fibre Channel adapter. The WWN is a
16-character hexadecimal number. The hyphens are not necessary but are
recommended to avoid mistakes in entering the number. The adapter ID
parameter name must be entered, followed by an equal sign, and then
followed by the WWN of the host bus adapter.