HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
66 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
To add a disk drive named DISK30200 as a non-transportable disk to port 3,
target 2, LUN 0 and set the data transfer rate to 10 MHz, enter the following on
one line:
ADD DISKS DISK30200 3 2 0 NOTRANSPORTABLE
TRANSFER_RATE_REQUESTED=10MHZ
To create a host-addressable unit after the disk is added, enter:
INITIALIZE DISK40200
ADD UNITS D199 DISK40200
See Also
ADD PASSTHROUGH
ADD UNITS
DELETE container-name
INITIALIZE
LOCATE
SET mirrorset-name
SET device-name
SET RAIDset-name
SHOW DISKS
SHOW DEVICES