HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
71HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
scsi-port-target-lun
Indicates the SCSI device PTL address. Place at least one space between the
port number, target number, and the LUN number after entering the PTL
address.
port—Designates the SCSI device port number, from 1 to 6, on which
the passthrough device resides.
target—Designates the SCSI target ID of the passthrough device on
the port. Valid device target IDs for single controller configurations are
00–15, excluding ID 7. Valid device target IDs for dual controller
configurations are 00–15, excluding IDs 6 through 7.
lun—Indicates the LUN of the passthrough device.
The parameters port, target, and lun must be entered with at least one space
between them. Leading zeroes can be excluded.
Switches
The following switch supports the ADD PASSTHROUGH command:
TRANSFER_RATE_REQUESTED
TRANSFER_RATE_REQUESTED
Specifies the maximum data transfer rate at which the controller is to
communicate with the passthrough device. The transfer rate might need to be
limited to accommodate long cables between the controllers and the device.
Valid values are listed below:
TRANSFER_RATE_REQUESTED=ASYNCHRONOUS
TRANSFER_RATE_REQUESTED=DEFAULT
TRANSFER_RATE_REQUESTED=20MHZ (default)
TRANSFER_RATE_REQUESTED=10MHZ
TRANSFER_RATE_REQUESTED=5MHZ
Examples
To add PASS10200 at port 1, target 2, LUN 0, enter:
ADD PASSTHROUGH PASS10200 1 2 0
ADD UNIT P4 PASS10200