HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
74 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
These parameters are described in the following paragraphs.
RAIDset-name
Assigns a name to the RAIDset. This is the name used with the ADD UNITS
command to identify the RAIDset as a host-addressable unit.
The RAIDset-name can consist of a maximum of nine printable characters
excluding commas and backslashes.
It is common to name a RAIDset RAIDn, where n is a sequentially assigned,
unique identifier. This naming convention presents the user with the type of
container and its unique identifier.
disk-name1 disk-name2 disk-name3 [disk-nameN]
Identifies the disks making up the RAIDset.
Switches
The following switches support the ADD RAIDSETS command:
POLICY and NOPOLICY
RECONSTRUCT
REDUCED and NOREDUCED
These switches are described in the following paragraphs.
POLICY=BEST_FIT
POLICY=BEST_PERFORMANCE
(default)
NOPOLICY
Sets the selection criteria the controller uses to choose a replacement member
from the spareset after a RAIDset member fails:
Specify POLICY=BEST_FIT to choose a replacement disk drive from
the spareset that equals or exceeds the base member size of the remaining
members of the RAIDset. If more than one disk drive in the spareset is the
correct size, the controller selects a disk drive giving the best
performance.
Specify POLICY=BEST_PERFORMANCE to choose a replacement disk
drive from the spareset resulting in the best performance of the RAIDset.
The controller attempts to select a disk on a different port than existing