HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
77HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Note: If you move a RAIDset from one controller to another, and the RAIDset becomes
reduced during the move, you cannot use the
REDUCED switch to recreate the
RAIDset. To recreate the RAIDset, you must:
1. Create a new RAIDset with the remaining original members.
2. Add a new disk (that is newly initialized) to complete the number of members
in the original set
without
using the REDUCED switch.
3. Observe that the system recognizes the newly added disk as not part of the
original RAIDset and moves it to the failedset.
4. Move the new disk from the failedset, and place it into the active RAIDset.
Refer to the
HP StorageWorks HSG60 and HSG80 Array Controller and Array
Controller Software Maintenance and Service Guide
for additional details.
See Also
ADD UNITS
DELETE container-name
INITIALIZE
SHOW RAIDSETS
SHOW RAIDSETS
SHOW raidset-name
SHOW STORAGESETS