HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
83HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Switches
The following switch supports the ADD SNAPSHOT_UNITS command:
USE_PARENT_WWID
Causes the snapshot unit to be created with a special World Wide ID (WWID)
derived from that of the parent or source unit. If the special WWID for the
specified source unit is in use, then a new WWID is automatically allocated,
and a warning message is displayed.
Note: The USE_PARENT_WWID switch limits the number of WWIDs that an
operating system needs to track. This can become an issue if snapshots are created
and subsequently deleted from the same source or parent unit on a regular basis.
Example
To create unit D4, which consists of storageset RAID4 and which becomes a
snapshot of unit D1, enter:
ADD SNAPSHOT_UNITS D4 RAID4 D1
See Also
SET unit-number
DELETE container-name
SHOW unit-number