HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
84 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Adds a disk drive to the spareset and initializes the metadata on the drive. The
spareset is a pool of drives available to the controller to replace failing storageset
members.
Syntax
ADD SPARESETS disk-name
Parameters
The following parameter supports the ADD SPARESETS command.
disk-name
Indicates the name of the disk drive being added to the spareset. Only one disk
drive can be added to the spareset with each ADD SPARESETS command.
Switches
There are no switches associated with this command.
Example
To add disk drives named DISK20200 and DISK30300 to a spareset, enter:
ADD SPARESETS DISK20200
ADD SPARESETS DISK30300
See Also
DELETE SPARESETS
SHOW SPARESETS
SHOW STORAGESETS
ADD SPARESETS