HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
88 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Creates a logical unit from a specified container. The controller maps all requests
from the host to the logical-unit number as requests to the container specified in
the ADD UNITS command. Units can be created from all container types:
Disk and passthrough devices
Stripesets
Mirrorsets
RAIDsets
Partitions
Striped mirrorsets
If adding a newly created container to a subsystem, the container must be
initialized in order to be added as a logical unit. If adding a container with
previously stored data that needs to be maintained, do not initialize this container;
the container is added as a logical unit.
Caution: Adding a unit immediately makes that unit available to all host
connections unless the
ENABLE_ACCESS PATH switch of the ADD
UNITS
command is specified as disabled.
Syntax
ADD UNITS unit-number container-name
Parameters
The following parameters are required for the ADD UNITS command:
unit-number
container-name
These parameters are described in the following paragraphs.
ADD UNITS