HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
97HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
If the controller pair is in Multiple-bus Failover mode, this unit can
potentially be seen by all four controller ports. It is presented to each host
connection as LUN (2 – offset). Offset is a host connection characteristic,
specified in the ADD CONNECTIONS (or SET connection-name)
command.
To create unit D5 from mirrorset MIRR1, and to let only two host connections
(Server1 and Server2) have access to this unit, enter:
ADD UNITS D5 MIRR1 DISABLE_ACCESS_PATH=ALL
SET UNITS D5 ENABLE_ACCESS_PATH=(SERVER1,SERVER2)
If the controller pair is in Transparent Failover mode, this unit is on port 1
and is available only to host connections Server1 and Server2. Server1
and Server2 must be connected to host port 1 to access the unit. The unit
is presented to each host connection as LUN (5 – offset). Offset is a host
connection characteristic, specified in the ADD CONNECTIONS (or SET
connection-name) command.
If the controller pair is in Multiple-bus Failover mode, this unit can
potentially be seen by all four controller ports but is accessible only by
host connections Server1 and Server2. It is presented to each host
connection as LUN (5 – offset).
To create unit D7 from a RAIDset named RAID9 and instruct the unit to take
advantage of the controller writeback caching feature, enter:
ADD RAIDSETS RAID9 DISK10100 DISK20100 DISK30100 DISK40100
INITIALIZE RAID9
ADD UNITS D7 RAID9 WRITEBACK_CACHE
See Also
CREATE_PARTITION
DESTROY_PARTITION
DELETE unit-number
SET connection-name
SET unit-number
SHOW unit-number