HP StorageWorks HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide (AA-RV1VA-TE, March 2005)

Preparing the Host System
113HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide
Solution Software Upgrade Procedures
Use the following procedures for upgrades to your Solution Software. It is
considered best practice to follow this order of procedures:
1. Perform backups of data prior to upgrade.
2. Verify operating system versions, upgrade operating systems to supported
versions and patch levels.
3. Quiesce all I/O and unmount all file systems before proceeding.
4. Upgrade solution software.
5. Upgrade ACS software.
Note: Solely for the purpose of performing upgrades to the ACS firmware, this Solution
Software Kit supports previous ACS V8.6 and V8.7. Do not mix ACS versions in the
same SAN.
Refer to the HP StorageWorks HSG60 and HSG80 Array Controller and Array
Controller Software Maintenance and Service Guide and the Solution Software
Release Notes for the latest information on upgrades.
Use the following installation and upgrade procedures for Tru64 UNIX systems:
Note: You must have the SNMP service installed on your client computer before the
installation.
1. Insert the Solution Software CD-ROM into a computer running Windows
2000 or Windows NT 4.0 with Service Pack 4 or later.
2. Using Microsoft Windows Explorer, go to the SWCC directory on the
CD-ROM and double-click
setup.exe. The SWCC Setup window will
appear.
3. Select HSG80 Controller for ACS85 new and click Next. Follow the
instructions on the screen.
Installing Agent
1. Insert the Solution Software CD-ROM into the host computer.