HP StorageWorks HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide (AA-RV1VA-TE, March 2005)

Preparing the Host System
122 HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide
In the event that all connections are enabled the display appears as follows.
HSG80> SHOW MANAGERS
Connection <<<All Connections Enabled>>>
Name Operating System Controller Port Address
Status
NEWCON14 AIX THIS 1 011000 OL
this 0
HOST_ID=2000-0000-C922-46E2
ADAPTER_ID=1000-0000-C922-46E2
NEWCON15 WINNT THIS 1 011200 OL
this 0
HOST_ID=2000-0000-C927-6735
ADAPTER_ID=1000-0000-C927-6735
NEWCON16 AIX OTHER 1 011100 OL
other 0
HOST_ID=2000-0000-C925-0096
ADAPTER_ID=1000-0000-C925-0096
NEWCON17 WINNT OTHER 1 011300 OL
other 0
HOST_ID=2000-0000-C923-2CD2
ADAPTER_ID=1000-0000-C923-2CD2
<<<All Connections Enabled>>>
Enabling SAN Security
To enable a secure SAN, use the connection table locking feature. In the following
example, the connection table is enabled, so no so no other host can login, all
management access is disabled and then a single host is enabled to have
management access.
CLI> SET THIS CONNECTIONS_LOCKED
CLI> SET DISABLE_MANAGERS=ALL
CLI> SET THIS ENABLE_MANAGERS=NEWCON17
From this point, the newly enabled host with management privileges or the CLI
can be utilized to enable other hosts as management agents.